18th Nov, 2009No Comments
Hi,
If you want to configure a serial console on your Dell PE R410 (or R710) server with CentOS 5.4 (or 5.3 and probably also the Red Hat Enterprise systems) you can use these guidelines.
In the Bios:Under "Serial Communication":
Serial Communication: On with Console Redirection via COM1
Serial Port Address: Serial Device1=COM2,Serial Device2=COM1
External Serial Connector: Serial Device2
Failsafe Baud Rate: 115200
Remote Terminal Type: VT100/VT220
Redirection After Boot: Enabled (so grub displays)Then you configure Grub:
title CentOS (2.6.18-164.6.1.el5) Serial
root (hd0,0)
kernel /vmlinuz-2.6.18-164.6.1.el5 ro root=LABEL=/ console=tty0 console=ttyS0,115200n8
initrd /initrd-2.6.18-164.6.1.el5.imgThis makes the kernel display it’s messages on screen and over the serial console.
In /etc/securetty append:
ttyS0
ttyS1This way root can log in using the serial console.
Finally configure the inittab (/etc/inittab) and add the following line:
co:2345:respawn:/sbin/agetty ttyS0 115200 linux
Now reboot and enjoy pure serial console goodness over ip (ipmi).
(Oh, don’t forget to enable IPMI over lan in the iDrac configuration and to set a username, password and ip-address.
The iDrac 6 configuration flashes by when the server boots.)Kind regards,
Koen
-
24th Sep, 2008No Comments
In order to use the serial console redirection of your Supermicro IPMI Board Management Card with open-source tools such as OpenIPMI’s ipmitool, you’ll have to upgrade your BMC’s firmware if necessary. A whole lot of cards have left the factory with the RMCP protocol on board, while ipmitool only supports serial console redirection when using the lanplus interface (RMCP+).
First, get the necessary software from Supermicro’s FTP site:
ftp://ftp.supermicro.com/CDR-0010_2.10_IPMI_Server_Managment/Firmware/IPMI20/
Check the readme.txt in the folder for the file you need for your motherboard, and download the correct zip file.
Unzip the contents of the archive to a bootable DOS diskette, a bootable USB stick or whatever bootable medium comes to hand first.
Boot from that medium, and launch the Setup.bat file from the DOS prompt. Do not power off your server during the BIOS upgrade!
After the upgrade, power off your server, and disconnect the power cable so the motherboard doesn’t get any power at all. This obscure fact isn’t mentioned in any documentation, but failure to do so will result in an unresponsive IPMI card.
Lastly, boot up your server, and configure your BMC card using ipmitool lan set commands.
Happy hunting!
Denis
-
10th May, 2007No Comments
Anyone who has ever played around with serial console operation, be it over a serial cable or with an IPMI-like serial redirection over LAN, has known the joys of trying to find working alternatives to the function keys. Since one of the things you’ll be likely to do with a serial console is to enter the BIOS setup, and entering the bios setup usually requires the use of F1, F2 or F10, this is a bit of a poser.
Luckily for us, Dell in it’s neverending wisdom has seen fit to display all necessary escape sequences for its Serial BIOS at boot time. The only hitch is that this screen flashes by so quickly that it’s impossible to read unless you’ve been gifted with x-ray eyes. Armed with the Print-Screen key and Photoshop, we did some twenty reboots of the server and were able to decipher the following shortcuts:
Dell Serial Bios keyboard shortcuts
F1 <ESC>1
F2 <ESC>2
F3 <ESC>3
F4 <ESC>4
F5 <ESC>5
F6 <ESC>6
F7 <ESC>7
F8 <ESC>8
F9 <ESC>9
F10 <ESC>0
F11 <ESC>!
F12 <ESC>@Home <ESC>h
End <ESC>k
Insert <ESC>+
Delete <ESC>-
PageUp <ESC>?
PageDn <ESC>/Use the <ESC><Ctrl><M> key sequence for <Ctrl><M>
Use the <ESC><Ctrl><H> key sequence for <Ctrl><H>
Use the <ESC><Ctrl><I> key sequence for <Ctrl><I>
Use the <ESC><Ctrl><J> key sequence for <Ctrl><J>
Use the <ESC><X><X> key sequence for <Alt><x>, where x is any letter key, and X is the upper case of that keyNote: Use your keypad for the <ESC>n sequences!
-
6th Apr, 2007No Comments
What happened to our networking?
Here we were, admiring our brand new Dell Poweredge 2950 server that we were going to use as a Xen host. Fedora Core 6 installed without a hitch, but when we tried booting the Xen kernel, we lost connectivity on the first network card for Dom0. The second NIC, which had not been tweaked by Xen’s bridging setup, still worked as a charm. So, regretfully, we set out to learn once again things we’d rather left unlearned…
Dell, Broadcom and the art of technical support
After googling around a bit, we found that the problem was hardly a new one. It appears that the Broadcom Netextreme II BCM5708 NIC’s that ship with the Dell Poweredge 2950 do not play ball with Xen’s bridging setup, at least not when support for Dell’s IPMI card ( DRAC ) is enabled. Xen does some internal tweaking with your network interfaces, and ends up assigning eth0’s mac address to a new virtual interface, which is Dom0’s eth0. The original eth0 gets renamed to peth0, and gets a mac address of ff:ff:ff:ff:ff:fe, since in normal circumstances this interface should not be visible on the LAN.
It appears that the Broadcom BCM5708 NIC’s filter out all traffic that is not directed at the NIC’s physical mac address, at least when the NIC’s management function is enabled. The funny thing is that this problem has been acknowledged by Dell as far back as the summer of 2006, but they haven’t seen fit to bring out a firmware update ro solve this problem. Calling Dell Support brought us no further: there’s nothing known about an eventual release of a patch. How the guys are going to cope with the new Suse Linux Enterprise Server 10 and Red Hat Enterprise Linux 5, both of whom proudly announce the wonders of Xen virtualisation, I don’t know.
Two solutions for the problem
The first, quick and dirty workaround, is to disable the management functions on your Broadcom NIC’s. Since this means going without IPMI support, and forgoing remote reboot and serial text console functionality , that’s more of a choice between Scylla and Charibdis. Anyway, this workaround is documented at:
How to disable the management function on Broadcom NetXtreme II BCM5708 NIC
We chose for a second solution, which is slightly more complex, but has the advantage of keeping IPMI connectivity intact. Since the Broadcom NIC’s require that the physical NIC’s mac addresses remain unchanged, we had to tweak Xen’s bridging scripts to allow this. Dom0’s network interfaces, which normally are assigned the physical NIC’s mac addresses, get a locally administered mac address out of Xen’s mac address range instead. Beware: you should take care to assign different addresses to all Xen servers on a same subnet, or you may experience connectivity problems to your Dom0’s.
So here’s what we did:
In you Xen config file, found at /etc/xen/xend-config.sxp in our installation, change the default network script to a custom one:
# comment this one out
#(network-script network-bridge)
# add this one
(network-script my-network-bridge)
Then you have to create your custom bridging script. Place it in /etc/xen/scripts/my-network-bridge - or the directory your xen scripts reside in. The script should contain the following lines - the second one is not strictly necessary if you only want top bridge one network interface:
#!/bin/sh
dir=$(dirname "$0")
# The mac addresses you assign here should be different for every server.
# Also, watch out for conflicts with your DomU’s mac addresses.
# Use the 00:16:3e:xx:xx:xx range, which is Xen’s assigned range
"$dir/network-bridge" "$@" vifnum=0 macaddr=00:16:3e:00:00:00
"$dir/network-bridge" "$@" vifnum=1 macaddr=00:16:3e:00:00:01Then finally, modify your network-bridge script like this - the changes are outlined in bold:
#!/bin/sh
#============================================================================
# Default Xen network start/stop script.
# Xend calls a network script when it starts.
# The script name to use is defined in /etc/xen/xend-config.sxp
# in the network-script field.
#
# This script creates a bridge (default xenbr${vifnum}), adds a device
# (default eth${vifnum}) to it, copies the IP addresses from the device
# to the bridge and adjusts the routes accordingly.
#
# If all goes well, this should ensure that networking stays up.
# However, some configurations are upset by this, especially
# NFS roots. If the bridged setup does not meet your needs,
# configure a different script, for example using routing instead.
#
# Usage:
#
# network-bridge (start|stop|status) {VAR=VAL}*
#
# Vars:
#
# vifnum Virtual device number to use (default 0). Numbers >=8
# require the netback driver to have nloopbacks set to a
# higher value than its default of 8.
# bridge The bridge to use (default xenbr${vifnum}).
# netdev The interface to add to the bridge (default eth${vifnum}).
# antispoof Whether to use iptables to prevent spoofing (default no).
#
# Internal Vars:
# pdev="p${netdev}"
# vdev="veth${vifnum}"
# vif0="vif0.${vifnum}"
#
# start:
# Creates the bridge
# Copies the IP and MAC addresses from netdev to vdev
# Renames netdev to be pdev
# Renames vdev to be netdev
# Enslaves pdev, vdev to bridge
#
# stop:
# Removes netdev from the bridge
# Transfers addresses, routes from netdev to pdev
# Renames netdev to vdev
# Renames pdev to netdev
# Deletes bridge
#
# status:
# Print addresses, interfaces, routes
#
#============================================================================dir=$(dirname "$0")
. "$dir/xen-script-common.sh"
. "$dir/xen-network-common.sh"findCommand "$@"
evalVariables "$@"vifnum=${vifnum:-$(ip route list | awk ‘/^default / { print $NF }’ | sed ’s/^[^0-9]*//’)}
vifnum=${vifnum:-0}
bridge=${bridge:-xenbr${vifnum}}
netdev=${netdev:-eth${vifnum}}
antispoof=${antispoof:-no}
# add a new macaddr parameter to the script
macaddr=${macaddr:-ff:ff:ff:ff:ff:ff}
pdev="p${netdev}"
vdev="veth${vifnum}"
vif0="vif0.${vifnum}"get_ip_info() {
addr_pfx=`ip addr show dev $1 | egrep ‘^ *inet’ | sed -e ’s/ *inet //’ -e ’s/ .*//’`
gateway=`ip route show dev $1 | fgrep default | sed ’s/default via //’`
}do_ifup() {
if ! ifup $1 ; then
if [ ${addr_pfx} ] ; then
# use the info from get_ip_info()
ip addr flush $1
ip addr add ${addr_pfx} dev $1
ip link set dev $1 up
[ ${gateway} ] && ip route add default via ${gateway}
fi
fi
}# Usage: transfer_addrs src dst
# Copy all IP addresses (including aliases) from device $src to device $dst.
transfer_addrs () {
local src=$1
local dst=$2
# Don’t bother if $dst already has IP addresses.
if ip addr show dev ${dst} | egrep -q ‘^ *inet ‘ ; then
return
fi
# Address lines start with ‘inet’ and have the device in them.
# Replace ‘inet’ with ‘ip addr add’ and change the device name $src
# to ‘dev $src’.
ip addr show dev ${src} | egrep ‘^ *inet ‘ | sed -e "
s/inet/ip addr add/
s@\([0-9]\+\.[0-9]\+\.[0-9]\+\.[0-9]\+/[0-9]\+\)@\1@
s/${src}/dev ${dst}/
" | sh -e
# Remove automatic routes on destination device
ip route list | sed -ne "
/dev ${dst}\( \|$\)/ {
s/^/ip route del /
p
}" | sh -e
}# Usage: transfer_routes src dst
# Get all IP routes to device $src, delete them, and
# add the same routes to device $dst.
# The original routes have to be deleted, otherwise adding them
# for $dst fails (duplicate routes).
transfer_routes () {
local src=$1
local dst=$2
# List all routes and grep the ones with $src in.
# Stick ‘ip route del’ on the front to delete.
# Change $src to $dst and use ‘ip route add’ to add.
ip route list | sed -ne "
/dev ${src}\( \|$\)/ {
h
s/^/ip route del /
P
g
s/${src}/${dst}/
s/^/ip route add /
P
d
}" | sh -e
}##
# link_exists interface
#
# Returns 0 if the interface named exists (whether up or down), 1 otherwise.
#
link_exists()
{
if ip link show "$1" >/dev/null 2>/dev/null
then
return 0
else
return 1
fi
}# Set the default forwarding policy for $dev to drop.
# Allow forwarding to the bridge.
antispoofing () {
iptables -P FORWARD DROP
iptables -F FORWARD
iptables -A FORWARD -m physdev –physdev-in ${pdev} -j ACCEPT
iptables -A FORWARD -m physdev –physdev-in ${vif0} -j ACCEPT
}# Usage: show_status dev bridge
# Print ifconfig and routes.
show_status () {
local dev=$1
local bridge=$2echo ‘============================================================’
ip addr show ${dev}
ip addr show ${bridge}
echo ‘ ‘
brctl show ${bridge}
echo ‘ ‘
ip route list
echo ‘ ‘
route -n
echo ‘============================================================’
}op_start () {
if [ "${bridge}" = "null" ] ; then
return
fiif ! link_exists "$vdev"; then
if link_exists "$pdev"; then
# The device is already up.
return
else
echo "
Link $vdev is missing.
This may be because you have reached the limit of the number of interfaces
that the loopback driver supports. If the loopback driver is a module, you
may raise this limit by passing it as a parameter (nloopbacks=<N>); if the
driver is compiled statically into the kernel, then you may set the parameter
using loopback.nloopbacks=<N> on the domain 0 kernel command line.
" >&2
exit 1
fi
ficreate_bridge ${bridge}
if link_exists "$vdev"; then
mac=`ip link show ${netdev} | grep ‘link\/ether’ | sed -e ’s/.*ether \(..:..:..:..:..:..\).*/\1/’`
preiftransfer ${netdev}
transfer_addrs ${netdev} ${vdev}
if ! ifdown ${netdev}; then
# If ifdown fails, remember the IP details.
get_ip_info ${netdev}
ip link set ${netdev} down
ip addr flush ${netdev}
fi
ip link set ${netdev} name ${pdev}
ip link set ${vdev} name ${netdev}# do not use the default bridging function as this resets the mac address
# setup_bridge_port ${pdev}# instead use the code below, which leaves the mac address intact
ip link set ${pdev} down
ip link set ${pdev} arp off
ip link set ${pdev} multicast off
ip addr flush ${pdev}
setup_bridge_port ${vif0}# do not assign pethX’s mac address to Dom0’s ethX
# ip link set ${netdev} addr ${mac} arp on# instead use the $macaddr parameter we passed to the script
ip link set ${netdev} addr ${macaddr} arp on
ip link set ${bridge} up
add_to_bridge ${bridge} ${vif0}
add_to_bridge2 ${bridge} ${pdev}
do_ifup ${netdev}
else
# old style without ${vdev}
transfer_addrs ${netdev} ${bridge}
transfer_routes ${netdev} ${bridge}
fiif [ ${antispoof} = 'yes' ] ; then
antispoofing
fi
}op_stop () {
if [ "${bridge}" = "null" ]; then
return
fi
if ! link_exists "$bridge"; then
return
fiif link_exists "$pdev"; then
ip link set dev ${vif0} down
mac=`ip link show ${netdev} | grep ‘link\/ether’ | sed -e ’s/.*ether \(..:..:..:..:..:..\).*/\1/’`
transfer_addrs ${netdev} ${pdev}
if ! ifdown ${netdev}; then
get_ip_info ${netdev}
fi
ip link set ${netdev} down arp off
ip link set ${netdev} addr fe:ff:ff:ff:ff:ff
ip link set ${pdev} down
ip addr flush ${netdev}# do not reassign pethX’s mac address, since it hasn’t changed
# ip link set ${pdev} addr ${mac} arp on
brctl delif ${bridge} ${pdev}
brctl delif ${bridge} ${vif0}
ip link set ${bridge} downip link set ${netdev} name ${vdev}
ip link set ${pdev} name ${netdev}
do_ifup ${netdev}
else
transfer_routes ${bridge} ${netdev}
ip link set ${bridge} down
fi
brctl delbr ${bridge}
}# adds $dev to $bridge but waits for $dev to be in running state first
add_to_bridge2() {
local bridge=$1
local dev=$2
local maxtries=10echo -n "Waiting for ${dev} to negotiate link."
ip link set ${dev} up
for i in `seq ${maxtries}` ; do
if ifconfig ${dev} | grep -q RUNNING ; then
break
else
echo -n ‘.’
sleep 1
fi
doneif [ ${i} -eq ${maxtries} ] ; then echo ‘(link isnt in running state)’ ; fi
add_to_bridge ${bridge} ${dev}
}case "$command" in
start)
op_start
;;stop)
op_stop
;;status)
show_status ${netdev} ${bridge}
;;*)
echo "Unknown command: $command" >&2
echo ‘Valid commands are: start, stop, status’ >&2
exit 1
esacFinally, comment out the mac addresses in the ifup scripts, else your OS will complain about setting up eth0 and eth1 with different mac addresses than those mentioned in the ifup scripts:
# Broadcom Corporation NetXtreme II BCM5708 Gigabit Ethernet
DEVICE=eth0
BOOTPROTO=static
BROADCAST=192.168.255.255
#HWADDR=00:1A:A0:05:12:AB
IPADDR=192.168.0.11
NETMASK=255.255.0.0
NETWORK=192.168.0.0
ONBOOT=yesRestart your services as needed, and you’ll be able to connect to your network interfaces without a hitch!